Uninterruptible Power Supplies (UPS).
Frequency Converters.
The UPS', single phase and
three phases, can be customized as following:
- UPS up to 200KVA
- Redundant UPS' (Hot Stand-By)
- Paralleled UPS'.
- Frequency Converters.
- No-Break UPS |
 |
In addition to a NORMALISED version, called MOSTECH, Convel
produces a series of STATIC GROUPS at customer request.
All the main functions, the signals, the alarms and other features, are made to
the customer’s Technical Specification.
All the UPS made by Convel incorporate the most recent technology including the
high frequency IGBT technology to give an output sinusoidal voltage without any
distortion (<2%) and/or other disturbances. The system used is pulse width
modulation (PWM).
Typically, these pieces of equipment are supplied with a static by-pass,
automatic switches on both the input and output sides and manual by-pass. The
main electronic board is fitted with a codified digital controller which
monitors the working state of the equipment in real time. The controller
produces a numeric code on a display to indicate the source of alarms and/or
faults, making the maintenance operations and return to service much quicker
than would otherwise be the case.
The type of battery used, may be sealed lead, stationary lead (open containers)
or Nickel-Cadmium. Their outputs and nominal voltages can be adapted to the
particular equipment (e.g. batteries already in place) or to the customer’s
requirements.
The cubicle painting, like that of the battery chargers, is a series operation
using epoxide powder, which is then oven treated. The thickness is at least 75µ,
in RAL 7032.
Painting can be carried out to other standards (BS, NEMA) and /or using
different colours for both framework, doors and panels.
All the internal fixings are tropicalised to give a long working life.
The internal cabling normally uses protective channels; and the cables
themselves are the flame-resistant type (CEI 20 - 22). For specific purposes, it
is possible to use low toxic emission flame resistant cables type AFUMEX CEI 20
- 38.
The minimum protection grade is IP 30 or IP 20 with the doors open. The
protection grade can be raised on request, or for special applications.
All UPS are supplied with full documentation, CE marking and conform to the Low
Voltage Directive CEE 73/23.
Consult the SYSTEMS page for further details of systems fitted with distribution
sections.
 |
UPS "MOSTECH" NORMALISED TABLE
TYPO |
POV.
kVA |
IMP
ING. |
BATTERY
Ah |
TIME.
min. |
WIDTH. |
HIGH. |
DEEP. |
WEIGHT
kg |
MST 2015
MST 2030
MST 2060
|
2
|
1/3
|
6x24
6x36
6x50
|
15
30
60
|
600
|
1200
|
600
|
230
250
290
|
MST 3515
MST 3530
MST 3560
|
3,5
|
1/3
|
9x24
9x36
9x50
|
15
30
60
|
600
|
1200
|
600
|
270
300
370
|
MST 5015
MST 5030
MST 5060
|
5
|
1/3
|
9x36
9x50
18x50
|
15
30
60
|
600
|
1200
|
600
|
360
430
550
|
MST 7515
MST 7530
MST 7560
|
7,5
|
3
|
18x24
18x36
Esterne
|
15
30
60
|
600
|
1700
|
600
|
470
530
310
|
MST 10015
MST 10030
MST 10060
|
10
|
3
|
18x36
18x50
Esterne
|
15
30
60
|
600
|
1700
|
600
|
600
720
370
|
|
|